Business Login   Business registration
 ABB AV31 AV 31 » For sale
Price : 520 USD

8618020776786 

Details :
AMIKON LIMITED
Sales Manager:Nancy
Email:info@amikon.cn
Whatsapp/Skype: + 8618020776786
Website: www.amikon.cn

Advantage Brands:

Allen Bradley: Reliance,SLC500/1747/1746,Logix5000/1756,PLC-5/1771/1785
ABB: DSQC series,H&B Freelance,Bailey
Bently Nevada: 3500 System spare parts ,3300 System spare parts
Yokogawa DCS
Honeywell DCS
Ovation: 1C31234G01/1C31227G01/1C31166G01/1C31116G01/1C31189G01 etc DCS System spare
GE: IC693/IC697/IS200/DS200/IS215
Triconex: 3700A/3805E/3604E/3503E/3504E/3008/4119A/8312/3703E/3511/
Schneider 140 PLC series 140CPU67160/140CRP93200/140CPS11420

AMIKON LIMITED to the "professional, integrity, innovation, cooperation, win-win"
business philosophy, and constantly develop new products, to provide quality services, in order
to maximize the pursuit of customer satisfaction, and constantly open up new areas of business for customers.

Relay outputs
Three programmable relay outputs
Switching capacity 8 A at 24 VDC or 250 VAC, 0.4 A at 120 VDC
Minimum continuous current 5 mA rms at 24 VDC
Maximum continuous current 2 A rms
Isolation test voltage 4 kVAC, 1 minute
DDCS fibre optic link
With optional communication adapter module RDCO. Protocol: DDCS (ABB
Distributed Drives Communication System)
24 VDC power input
Voltage 24 VDC ± 10%
Typical current consumption
(without optional modules)
250 mA
Maximum current consumption 1200 mA (with optional modules inserted)
The terminals on the RMIO board as well as on the optional modules attachable to the board fulfil the Protective Extra
Low Voltage (PELV) requirements stated in EN 50178 provided that the external circuits connected to the terminals also
fulfil the requirements and the installation site is below 2000 m (6562 ft). Above 2000 m (6562 ft)

External control connections (US)
External control cable connections to the RMIO board for the ACS800 Standard
Application Program (Factory Macro US version) are shown below. For external
control connections of other application macros and programs, see the appropriate
Firmware Manual.

External control connections (non-US)
External control cable connections to the RMIO board for the ACS800 Standard
Application Program (Factory Macro) are shown below. For external control
connections of other application macros and programs, see the appropriate
Firmware Manual.

JAICR-1100

CIMR-J7AA20P1

322U12084

VI 2000 V1.0

KST-2000

6KE$223005X1A1

SGDM-A5ADA

RORZE RC-233

PCB 681-0181-009

ITV2011-31N3N4-X95

0210X-BA24-AXN1/0324

IVG-7300

E-710K126

NP420-DN1

EBE-1073-51

4S018-908-1

VE0837A01

VE0831A05

Barnant 900-1174

PCI-1753-B

KEYENCE HC-P1E

E1725A

CHRAF2-450-N6

NF 1.100 KTDC

UTX-F5500-016

RMO-S594

PS 0090-A3931

VG A1300

S20330-VTS

SMS749